| Frequency Range |
|
| Bandwidth |
DC, 10mHz ~ 1MHz x10 DC, 10mHz ~ 100kHz |
| Voltage Input |
|
| Internal Ranges |
Normal : 1Vpk ~ 2500Vpk (8 ranges) x10 100mVpk ~ 300Vpk (8 ranges) |
| Internal Accuracy |
Normal : 0.05% Rdg + 0.1% Rng + (0.005%xkHz) + 5mV x10 : 0.05% Rdg + 0.1% Rng + (0.01%xkHz) + 1mV |
| External Voltage BNC Input Ranges |
1mVpk ~ 3Vpk in 8 ranges [BNC Connector 3Vpk Max Input] |
| External Voltage Input Accuracy |
0.05% Rdg + 0.1% Rng + (0.005%xkHz) + 5uV |
| Current Input |
|
| PPA1500 20Arms Shunt, 4mm Safety Connectors |
Normal : 100mApk ~ 300Apk (20Arms) (8 ranges) x10 : 10mApk ~ 300Apk (8 ranges) |
| PPA1500-HC 30Arms Shunt, 4mm Safety Connectors |
Normal : 300mApk ~ 1000Apk (30Arms) (8 ranges) x10 : 30mApk ~ 100Apk (8 ranges) |
| Internal Shunt Accuracy 20Arms |
Normal : 0.05% Rdg + 0.1% Rng + 0.005%xkHz) + 500uA x10 : 0.05% Rdg + 0.1% Rng + 0.01%xkHz) + 100uA |
| Internal Shunt Accuracy HC 30Arms |
Normal : 0.05% Rdg + 0.1% Rng + 0.005%xkHz) + 1mA x10 : 0.05% Rdg + 0.1% Rng + 0.01%xkHz) + 300uA |
| External Current BNC Input Ranges |
1mVpk ~ 3Vpk (8 ranges) |
| External Current Input Accuracy |
0.05% Rdg + 0.1% Rng + (0.005%/kHz) + 5uV |
| Phase Accuracy |
|
| Normal |
0.01deg + (0.01deg/kHz) |
| x10 |
0.01deg + (0.02deg/kHz) |
| Power Accuracy |
|
| Normal |
[0.1% + 0.1%/pf + (0.01%/kHz)/pf] Rdg + 0.1% VA Rng |
| x10 |
[0.1% + 0.1%/pf + (0.02%/kHz)/pf] Rdg + 0.1% VA Rng |
| 40Hz ~ 850Hz |
As above with range error reduced from +0.1% V,A,VA Rng to +0.05% V,A, VA Rng |
| General |
|
| Crest Factor |
20 (Voltage and Current) |
| Sample Rate |
1Ms/s on all channels, real time No-Gap |
| IEC Compliant Modes |
IEC62301/EN50564 Standby Power Mode |
| Application Modes |
Ballast, Inrush, Standby Power |
| CMRR - Common Mode Rejection Ratio |
250V @ 50Hz – ≥ 1mA (150dB) 100V @ 100kHz – ≥ 3mA (130dB) |
| Measurement Parameters |
W, VA, Var, pf, V & A – rms, rectified mean, AC, DC, peak, surge, crest factor, form factor, star to delta conversion, delta to star conversion |
| |
Frequency (Hz), Phase (deg), Fundamentals, Impedance |
| |
Harmonics, THD, TIF, THF, TRD, TDD |
| |
Integrated Values, Datalog, Sum and Neutral Values |
| Datalog |
(Up to 4 user selectable measurement functions (60 with PC software) |
| Datalog window |
No-Gap analysis, Minimum Window 10ms |
| Memory |
RAM up to 16,000 records |
| Communication Ports |
RS232, LAN, (Option L), USB, Extension (Aux) |
| Standard Accessories |
|
| Leads |
Power, RS232, USB |
| Connection Cables |
20A (Std Version) or 30A (HC version) 1.5m long 4mm stackable terminals. 1x red, 1x yellow, 2x black per phase |
| Connection Clips |
4mm terminated alligator clips – 1x red, 1x yellow and 2x black per phase |
| Instruction manual |
User manual, Communications manual |
| Other documents |
Calibration certificate, Quick start guide |
| Mechanical and Environmental |
|
| Display |
480×272 dot full colour TFT, White LED backlit |
| Dimensions |
92H x 215W x 312D mm excluding feet |
| Weight |
3.3kg (1 Phase), 4kg (3 Phase) |
| Safety Isolation |
1000Vrms or DC (CATII), 600Vrms or DC (CATIII) |
| Power Supply |
90 ~ 265Vrms, 50 ~ 60Hz, 40VA Max |
| Operating Conditions |
5 deg to 40 deg ambient temperature (or air intake temperature when rack mounted), 20-90% Non-condensing relative humidity. |