Selective Level Meter |
|
Frequency Range |
5Hz to 5MHz |
Frequency Accuracy |
±0.03% over all temperature range |
Magnitude Accuracy |
< 1KHz: 0.05% rng + 0.05% rdg + 50μV < 10KHz: 0.05% rng + 0.05% rdg + 0.01%/kHz +50μV < 5MHz: 0.05% rng + 0.25% rdg + 0.001%/kHz +50μV |
Inputs (Unbalanced) Type & Connection |
Differentially Isolated & Isolated BNC |
Bandwidth Settings |
3, 25, 100, 360, 400, 1.95k, 3.1k HZ & Wideband |
High Voltage Input |
|
Max Input |
±300V peak |
Input Impedance |
1MΩ ±5% // 30pF |
75Ω Input |
|
Max Input |
10W (28Vrms) |
Input Impedance |
75Ω ±1% // 30pF |
Low Level Input |
|
Max Input |
±10V peak |
Input Impedance |
75Ω ±1% // 30pF 120Ω ±1% // 30pF 150Ω ±1% // 30pF 600Ω ±1% // 30pF 1MΩ ±1% // 30pF |
Input Balanced |
|
Max Input |
±10V peak |
Input Impedance |
75Ω ±1% // 30pF 120Ω ±1% // 30pF 150Ω ±1% // 30pF 600Ω ±1% // 30pF 1MΩ ±1% // 30pF |
Input Type |
Differential |
Input Connection |
3 x 4mm connectors: Positive, Negative & Ground |
Signal Generator |
|
Generator Type |
Direct Digital Synthesis (DDS), single frequency or sweep |
Generator Waveforms |
Sinewave, Square, Triangle, White Noise |
Frequency Accuracy |
5ppm over all temperature range |
Magnitude Accuracy |
± 1% ± 1%/MHz (Low Level Output) ± 2.5% ± 1%/MHz (High Level Output) |
Hi Level Output |
|
Frequency Range |
5Hz to 5MHz |
Output Level |
2W into 75Ω (10V rms) |
Output Impedance |
75Ω ±2% |
Lo Level Output |
|
Frequency Range |
5Hz to 5MHz |
Output Level |
5Vrms into high impedance |
Output Impedance |
75Ω ±2% +22dBm 120Ω ±2% +20dBm 150Ω ±2% +19dBm 600Ω ±2% +15dBm |
Frequency Shift Delay Timer |
0 to 1s (1ms steps) |
Impedance Analyzer |
|
Impedance Range |
100 milli Ohm to 100 Kilo Ohm |
Accuracy |
< 10KHz: 1% rdg < 1MHz: 1% rdg + 0.005%/KHz +50μV < 5MHz: 5% rdg + 0.002%/KHz +50μV |
Features |
LCR Measurements (Inductance, Capacitance, Resistance, tan delta, QF) Lead Compensation (zero lead function) Impedance versus Frequency Curve |
Oscilloscope |
|
Sample Rate |
5M samples/s |
Timebase |
5μs/div to 5s/div |
Trigger |
Auto, Normal or Single Shot |
Pretrigger |
None, 25%, 50%, 75% |
Input Ranges |
As Selective Level Meter |
Second Input |
±10V peak 1MΩ ±5% // 30pF |
VSWR Meter |
|
Accuracy |
1% of reading up to 1MHz. 5% of reading above 1MHz to 5MHz for power measurements (forward and reflected) at VSWR = 3 |
Features |
Forward Power, Reflected Power, % Reflected Power, & Frequency under test visible on one screen |
Frequency Response Analyzer |
|
Frequency range |
5Hz to 5MHz |
Gain Accuracy dB |
0.02dB < 1KHz 0.05dB < 10KHz 0.1dB + 0.001dB/KHz |
Phase Accuracy ⁰ |
0.02⁰ < 10KHz 0.02⁰ + 0.003⁰ / KHz |
General Specifications |
|
Sweep Steps |
Up to 2000 in all sweep functions |
Set Up and Data Storage |
Up to 1000 analyser setups, readings and sweep results can be stored |
Interface |
USB, RS232, LAN |
Real Time Clock |
Time and date stamp for data stores |
Data Storage |
Internal 1GB flash, External USB pen port |
Display Type |
5.7" 1/4 VGA colour, high brightness backlight |
Display resolution |
6 digit frequency, 5 digit voltage, 4 digit dBm |
Size |
Approx: 305 x 230 x 45mm "tablet" style |
Power Source |
9-18V @ 3A AC adapter or 12V dc from car or external batteries |
Battery type and Battery Life |
10 x AA size NiMH Up to approx. 2 hours |
Temperature Range |
-5 to +50⁰ C |